You can contact us 24/7+971 55 290 0889
The Schneider Electric A9N61501 Acti9 C60H-DC is a 1A 1-pole C-curve DC MCB with 6kA breaking capacity at 250V DC, designed for overload and short-circuit protection, control and isolation of DC circuits.
The Schneider Electric Acti9 C60H-DC A9N61509 is a 13A 1P C-curve DC MCB with 6kA breaking capacity and a 250V DC rating per pole. It provides thermal-magnetic protection against overload and short-circuit currents in DC electrical circuits and complies with IEC/EN 60947-2.
The Schneider Electric MasterPact NW20H1 48064 is a 2000A 4-pole fixed Air Circuit Breaker with 65kA breaking capacity at 440V AC, rated up to 690V AC and supplied without a trip/control unit. It is designed for high-capacity LV power distribution and protection applications.
Schneider Electric MasterPact NW20H2 2000A 4-Pole Fixed ACB – 100kA, Without Trip Unit
The Schneider Electric MasterPact NW20H2 48065 is a 2000A, 4-pole fixed Air Circuit Breaker (ACB) designed for high-capacity low-voltage power distribution. Its H2 performance class provides 100kA Icu at 440V AC, with a rated operational voltage up to 690V AC. The breaker is supplied without a MicroLogic trip/control unit.
The Schneider Electric MasterPact NW25H1 48070 is a 2500A, 3-pole fixed Air Circuit Breaker (ACB) designed for high-capacity low-voltage power distribution. It provides 65kA short-circuit breaking capacity at 440V AC, supports operation up to 690V AC, and is supplied as a bare breaker frame without a trip/control unit.
Schneider Electric MasterPact NW25H1 2500A 4-Pole Fixed ACB with MicroLogic 2.0E – 65kA, Ref. 48076
The Schneider Electric MasterPact NW32H1 48087 is a 3200A, 4-pole fixed Air Circuit Breaker (ACB) designed for high-capacity low-voltage power distribution. It features 65kA short-circuit breaking capacity, a 690V AC operating voltage, Category B selectivity, and is supplied without a trip/control unit.
Key Product Highlights
- 3200A rated current
- 4-pole fixed ACB
- 65kA Icu at 440V AC
- 65kA Ics
- 65kA Icw for 1s / 3s
- 690V AC rated operational voltage
- 1000V AC insulation voltage
- 12kV impulse withstand voltage
- Category B utilization
- Suitable for isolation
- Without trip/control unit
- IEC 60947-2 compliant
- ASTA certified
- Fixed mounting configuration
The Schneider Electric MasterPact NW40H1 48097 is a 4000A, 4-pole fixed air circuit breaker (ACB) frame designed for high-capacity low-voltage power distribution. It features an H1 performance level with 65kA Icu at 440V AC, 690V AC rated operational voltage, and is supplied without a control/trip unit.
Schneider Electric MasterPact NW50H1 5000A 4-Pole Fixed ACB – 100kA, Without Trip Unit
The Schneider Electric MasterPact NW50H1 48115 is a 5000A 4-pole fixed air circuit breaker (ACB) frame for high-capacity low-voltage power distribution. It provides 100kA Icu and Ics at 440V AC, supports operation up to 690V AC, and is supplied without a Micrologic control/trip unit.
Schneider Electric MasterPact NW63H1 6300A 4-Pole Fixed ACB – 100kA, Without Trip Unit
The Schneider Electric MasterPact NW63H1 48121 is a 6300A, 4-pole fixed air circuit breaker (ACB) basic frame designed for high-capacity low-voltage power distribution. It features 100kA ultimate and service breaking capacity at 440V AC, a 690V AC rated operational voltage, and is supplied without a Micrologic trip/control unit.
Schneider Electric MasterPact NW16H1 1600A 3-Pole Drawout ACB – 65kA, Without Trip Unit
The Schneider Electric MasterPact NW16H1 48273 is a 1600A, 3-pole drawout air circuit breaker (ACB) for low-voltage power distribution protection. It features an H1 performance level with 65kA breaking capacity at 440V AC, a 690V AC rated operational voltage, and is supplied without a Micrologic trip/control unit.
Schneider Electric MasterPact NW25H1 2500A 4-Pole Drawout Air Circuit Breaker – 65kA, Without Trip Unit
The Schneider Electric MasterPact NW25H1, reference 48306, is a 2500A, 4-pole drawout air circuit breaker (ACB) designed for low-voltage power distribution protection. It has an H1 performance level with 65kA breaking capacity at 440V AC and is supplied without a control/trip unit.
The Schneider Electric LRD16 is a TeSys LRD differential thermal overload relay with an adjustable 9–13A thermal protection range and Class 10A tripping characteristic according to IEC 60947-4-1. It is designed for motor overload and phase-failure protection and is suitable for use with compatible TeSys D contactors.
The Schneider Electric LRD21 is a TeSys LRD / TeSys Deca differential thermal overload relay designed for motor protection against overload and phase failure. It provides an adjustable 12–18A thermal protection range with a Class 10A trip characteristic and is compatible with LC1D18, LC1D25, LC1D32 and LC1D38 TeSys D contactors.
The Schneider Electric LRD22 is a TeSys LRD differential thermal overload relay designed for motor protection against thermal overload and phase failure. It provides an adjustable 16–24A thermal protection range with Class 10A characteristics and is compatible with LC1D25, LC1D32 and LC1D38 TeSys D contactors.
The Schneider Electric LRD325 is a TeSys LRD differential thermal overload relay designed for reliable motor protection. It provides an adjustable 17–25A thermal protection range with Class 10A tripping characteristics and is suitable for use with compatible TeSys D contactors.