Schneider Electric MasterPact NW63H1 6300A 4-Pole Fixed ACB – 100kA, Without Trip Unit
The Schneider Electric MasterPact NW63H1 48121 is a 6300A, 4-pole fixed air circuit breaker (ACB) basic frame designed for high-capacity low-voltage power distribution. It features 100kA ultimate and service breaking capacity at 440V AC, a 690V AC rated operational voltage, and is supplied without a Micrologic trip/control unit.
Description
The Schneider Electric MasterPact NW63H1 is the highest-current 6300A frame in the MasterPact NW range, intended for large industrial and infrastructure LV switchboards where very high current-carrying and short-circuit capabilities are required. Reference 48121 is the 4-pole fixed-mount basic frame and is supplied without a protection/control unit.
With an H1 breaking-capacity class, the MasterPact NW63H1 48121 provides 100kA Icu and Ics at 440V AC. The breaker has a 6300A rated current, 1000V insulation voltage, and 12kV impulse withstand voltage, making it suitable for demanding high-current LV distribution applications.
The 4-pole configuration allows switching of the three phases and neutral. This makes it suitable for applications where neutral switching/isolation is required, subject to the electrical system design and applicable standards. The fixed construction is intended for permanent installation in the switchboard and should not be presented as a field-convertible drawout unit.
Reference 48121 is a basic frame without a trip unit. A compatible Micrologic control unit must be selected separately according to the required overload, short-circuit, earth-fault, metering and communication functions.
| Specification | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Product Range | MasterPact NW |
| Circuit Breaker Name | MasterPact NW63H1 |
| Reference / Catalogue Number | 48121 |
| Replacement Reference | LV948121 |
| Product Type | Air Circuit Breaker (ACB) Basic Frame |
| Application | Low-Voltage Power Distribution |
| Rated Current (In) | 6300A |
| Number of Poles | 4P / 4 Pole |
| Mounting Mode | Fixed |
| Control / Trip Unit | Without Trip / Control Unit |
| Performance Level | H1 |
| Rated Operational Voltage (Ue) | 690V AC, 50/60Hz |
| Rated Insulation Voltage (Ui) | 1000V AC, 50/60Hz |
| Rated Impulse Withstand Voltage (Uimp) | 12kV |
| Rated Ultimate Breaking Capacity (Icu) | 100kA at 440V AC |
| Rated Service Breaking Capacity (Ics) | 100kA at 440V AC |
| Rated Short-Time Withstand Current (Icw) | 100kA for 1s; 100kA for 3s |
| Rated Short-Circuit Making Capacity (Icm) | 220kA at 525V AC |
| Utilization / Selectivity Category | Category B |
| Suitability for Isolation | Yes, conforming to IEC 60947-2 |
| Network Type | AC |
| Rated Frequency | 50/60Hz |
| Control Type | Push-button / manually operated |
| Circuit Breaker CT Rating | 6300A |
| Protection Type | Without Protection / Trip Unit |
| Maximum Breaking Time | 25ms |
| Closing Response Time | <80ms |
| Connection Pitch | 230mm |
| Mechanical Durability | 5,000 cycles without maintenance / 10,000 cycles with maintenance |
| Electrical Durability | AC-3: 6,000 cycles at 440/690V AC without maintenance |
| Ambient Operating Temperature | -25°C to +70°C |
| Neutral Position | Left |
| Main Connection | Bolted connection |
| Standard | IEC 60947-2 |
| Certification | ASTA |
| Mercury Free | Yes |
| RoHS | Applicable / exemption information available |
| Weight | Approx. 145.13kg |
Key Features
- 6300A rated current
- 4-pole / 4P configuration
- MasterPact NW63H1 air circuit breaker frame
- Fixed-mount construction
- 100kA H1 breaking capacity
- 100kA Icu and Ics at 440V AC
- 690V AC rated operational voltage
- 1000V rated insulation voltage
- 12kV impulse withstand voltage
- 100kA short-time withstand current
- 220kA short-circuit making capacity at 525V AC
- Category B selectivity
- Suitable for isolation according to IEC 60947-2
- Without Micrologic trip/control unit
- Manual push-button operation
- Designed for high-capacity LV power distribution
- 4-pole neutral switching capability
- Suitable for main incomer and bus-tie applications
Applications
The Schneider Electric MasterPact NW63H1 6300A 4P ACB is suitable for:
- Main incomer protection
- High-capacity LV switchboards
- Bus coupler / bus-tie applications
- Industrial power distribution
- Large commercial electrical installations
- Infrastructure power systems
- Data-centre power distribution
- Generator and mains changeover systems where 4-pole switching is required
- High-current feeder protection
- Large manufacturing facilities
- Utility and infrastructure switchboards
- 6300A low-voltage power distribution systems
For applications requiring specific protection functions, the appropriate Micrologic control unit and accessories must be selected separately.
Only logged in customers who have purchased this product may leave a review.

Reviews