Schneider Electric EZC100N3100 EasyPact EZC100N 100A 3P 3D MCCB – TM-D

110.00 AED
In Stock

The Schneider Electric EZC100N3100 is a 100A 3P 3D MCCB with a TM-D thermal-magnetic trip unit for overload and short-circuit protection. It provides 15kA Icu at 400/415V AC, 690V insulation voltage and 550V maximum operational voltage for low-voltage electrical distribution applications.

In Stock
Add to wishlist1 person favorited this product
Categories: ,
Brand:

Description

The Schneider Electric EZC100N3100 is a 100A 3-pole 3D MCCB from the EasyPact EZC100N range, designed for reliable protection of low-voltage electrical distribution systems. This Schneider 100A MCCB features a TM-D thermal-magnetic trip unit that provides protection against both overload and short-circuit conditions.

The EasyPact EZC100N3100 MCCB has a 3P 3D configuration, meaning all three poles are protected. It is designed primarily for AC distribution networks operating at 50/60Hz, with a rated current of 100A. The circuit breaker supports a maximum rated operational voltage of 550V AC and a rated insulation voltage of 690V AC.

For installations operating at 400/415V AC, the EZC100N3100 provides an ultimate breaking capacity (Icu) of 15kA according to IEC 60947-2. The breaking capacity increases to 18kA at 380V AC, while the specified Icu is 10kA at 440V AC. At 220–240V AC, the breaker provides up to 25kA Icu. This makes the Schneider EZC100N3100 100A MCCB suitable for a range of low-voltage distribution applications where the prospective short-circuit current is within the specified limits.

The TM-D thermal-magnetic trip unit combines thermal overload protection and magnetic short-circuit protection in a compact MCCB design. The trip unit is rated at 100A at 50°C, while Schneider documentation specifies the device’s rated current as 100A under the applicable temperature conditions.

The EasyPact EZC100N 100A circuit breaker is a fixed-mount MCCB with backplate mounting, front connections and toggle operation. It also provides positive contact indication and is suitable for isolation according to IEC 60947-2. The compact design makes it suitable for installation in electrical distribution boards, switchboards and industrial control panels.

The EZC100N3100 has a rated insulation voltage of 690V AC, rated impulse withstand voltage of 6kV, and an operational voltage of up to 550V AC. The breaker is classified as Category A and has a pollution degree of 3, making it suitable for appropriately designed low-voltage electrical installations.

The Schneider Electric EZC100N3100 is therefore a practical solution for 100A feeder protection, distribution boards, commercial buildings, industrial electrical panels and low-voltage power distribution systems where thermal overload and short-circuit protection are required.

Lifecycle note: Schneider’s regional websites currently show different lifecycle information. Schneider Brazil lists the EZC100N3100 as discontinued on 31 May 2026, with standard service ending 30 June 2026, and states that it has not been replaced. Other Schneider regional pages continue to list the product. Therefore, lifecycle and availability should be verified for the target market before procurement.

Specification Details
Manufacturer Schneider Electric
Product Reference EZC100N3100
Product Range EasyPact EZC
Product Family EasyPact EZC100N
Product Type Molded Case Circuit Breaker (MCCB)
Device Application Distribution
Number of Poles 3P
Protected Poles 3D / 3T
Rated Current 100A
Trip Unit TM-D
Trip Technology Thermal-Magnetic
Trip Unit Rating 100A at 50°C
Network Type AC / DC
Network Frequency 50/60Hz
Rated Insulation Voltage (Ui) 690V AC
Rated Operational Voltage (Ue) 550V AC / 250V DC
Rated Impulse Withstand Voltage (Uimp) 6kV
Breaking Capacity Code N
Icu at 380V AC 18kA
Icu at 400/415V AC 15kA
Icu at 440V AC 10kA
Icu at 220–240V AC 25kA
Icu at 110–130V AC 25kA
Icu at 550V AC 5kA
Icu at 250V DC, 2P 5kA
Icu at 125V DC, 1P 5kA
Ics at 400/415V AC 7.5kA
Ics at 440V AC 5kA
Ics at 380V AC 9kA
Ics at 220–240V AC 12.5kA
Ics at 110–130V AC 12.5kA
Utilisation Category Category A
Overload Protection Yes
Short-Circuit Protection Yes
Suitability for Isolation Yes, IEC 60947-2
Control Type Toggle
Mounting Fixed
Mounting Support Backplate
Connections Front
Local Indication Positive contact indication
Earth-Leakage Protection Without
Neutral Protection Without neutral protection
Pollution Degree 3
Connection Pitch 25mm
Approx. Height 130mm
Approx. Width 75mm
Approx. Depth 60mm
Mechanical Durability 8,500 cycles
Electrical Durability 1,500 cycles at 415V AC, Category A
Standard IEC 60947-2

Key Features

  • Schneider Electric EZC100N3100 MCCB.
  • EasyPact EZC100N product range.
  • 100A rated current.
  • 3-pole 3D configuration.
  • TM-D thermal-magnetic trip unit.
  • Provides overload protection.
  • Provides short-circuit protection.
  • 15kA Icu at 400/415V AC.
  • 18kA Icu at 380V AC.
  • 10kA Icu at 440V AC.
  • Up to 25kA Icu at 220–240V AC.
  • 690V AC rated insulation voltage.
  • 550V AC rated operational voltage.
  • 6kV impulse withstand voltage.
  • 50/60Hz AC network compatibility.
  • Suitable for electrical isolation according to IEC 60947-2.
  • Fixed backplate mounting.
  • Front connection configuration.
  • Toggle-operated control.
  • Positive contact-position indication.
  • Category A circuit breaker.
  • 25mm connection pitch.
  • Compact EasyPact EZC design.

Applications

  • 100A feeder protection
  • Low-voltage power distribution
  • Industrial electrical distribution
  • Commercial electrical distribution
  • Distribution boards
  • Main electrical panels
  • Sub-distribution panels
  • Industrial control panels
  • Electrical switchboards
  • Factory power distribution
  • Building electrical systems
  • Overload protection
  • Short-circuit protection
  • Three-phase AC circuit protection

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.