Schneider Electric EZC100N3063 EasyPact EZC100N 63A 3P 3D MCCB – 15kA, TM-D

156.93 AED
In Stock

The Schneider Electric EZC100N3063 is a 63A 3P 3D MCCB with a TM-D thermal-magnetic trip unit for overload and short-circuit protection. It provides 15kA Icu at 415V AC, 690V insulation voltage and 550V maximum AC operational voltage for low-voltage electrical distribution applications.

In Stock
Add to wishlist1 person favorited this product
Categories: ,
Brand:

Description

The Schneider Electric EZC100N3063 is a 63A 3-pole 3D MCCB from the EasyPact EZC100N range, designed for protection and isolation in low-voltage electrical distribution systems. This Schneider 63A MCCB uses a TM-D thermal-magnetic trip unit to provide protection against electrical overloads and short-circuit faults. Schneider Electric identifies EZC100N3063 as an EasyPact EZC100N, 63A, 3-pole 3D circuit breaker.

The EasyPact EZC100N3063 MCCB has a 3P 3D configuration, with all three poles protected. It is suitable for AC and DC networks, with a network frequency of 50/60Hz for AC applications. The circuit breaker has a 63A rated current at 40°C, a 690V AC rated insulation voltage, and a maximum rated operational voltage of 550V AC. It is also specified for 250V DC operation under IEC 60947-2.

For standard 400/415V AC distribution, the EZC100N3063 provides an ultimate breaking capacity (Icu) of 15kA at 415V AC. Its Icu is 18kA at 380–400V AC, 10kA at 440V AC, and 25kA at 110–130V AC and 220–240V AC. At higher voltage levels, the specified Icu is 5kA at 550V AC. These ratings allow the Schneider EZC100N3063 63A MCCB to be selected according to the prospective short-circuit current of the installation.

The TM-D thermal-magnetic trip unit combines thermal overload protection with magnetic short-circuit protection. The trip unit rating is 63A at 50°C, while the breaker itself has a rated current of 63A at 40°C according to the product data. This combination provides straightforward protection for feeders and distribution circuits without requiring an electronic trip unit.

The EasyPact EZC100N 63A circuit breaker is a fixed MCCB with backplate mounting, front connections and toggle operation. It provides positive contact indication and is suitable for electrical isolation according to IEC 60947-2. Its compact dimensions of approximately 75mm wide × 130mm high × 60mm deep make it suitable for electrical panels and distribution boards where installation space is important.

The EZC100N3063 has a 6kV rated impulse withstand voltage (Uimp) and is classified as Category A. The breaker has a 25mm connection pitch, pollution degree 3, and a fixed construction intended for distribution applications. Schneider’s product information also identifies the EasyPact EZC100N range as a compact solution for standard industrial and building distribution applications.

For applications requiring a 63A 3-phase MCCB, the Schneider Electric EZC100N3063 offers a combination of thermal-magnetic protection, 15kA breaking capacity at 415V AC, compact dimensions and IEC 60947-2 compliance. It can be used for feeder protection, distribution boards, industrial panels, commercial electrical systems and low-voltage power distribution.

Specification Details
Manufacturer Schneider Electric
Product Reference EZC100N3063
Product Range EasyPact EZC
Product Family EasyPact EZC100N
Product Type Molded Case Circuit Breaker (MCCB)
Device Application Distribution
Number of Poles 3P
Protected Poles 3D / 3T
Rated Current (In) 63A at 40°C
Trip Unit TM-D
Trip Unit Technology Thermal-Magnetic
Trip Unit Rating 63A at 50°C
Network Type AC / DC
Network Frequency 50/60Hz
Rated Insulation Voltage (Ui) 690V AC
Rated Operational Voltage (Ue) 550V AC / 250V DC
Rated Impulse Withstand Voltage (Uimp) 6kV
Breaking Capacity Code N
Icu at 380–400V AC 18kA
Icu at 400/415V AC 15kA
Icu at 440V AC 10kA
Icu at 220–240V AC 25kA
Icu at 110–130V AC 25kA
Icu at 550V AC 5kA
Icu at 125V DC, 1P 5kA
Icu at 250V DC, 2P 5kA
Ics at 415V AC 7.5kA
Ics at 380–400V AC 9kA
Ics at 440V AC 5kA
Ics at 220–240V AC 12.5kA
Ics at 110–130V AC 12.5kA
Ics at 550V AC 2.5kA
Ics at 125V DC 2.5kA
Ics at 250V DC 2.5kA
Utilisation Category Category A
Overload Protection Yes
Short-Circuit Protection Yes
Suitability for Isolation Yes, IEC 60947-2
Control Type Toggle
Mounting Mode Fixed
Mounting Support Backplate
Connections Front
Local Indication Positive contact indication
Neutral Protection Without protection
Earth-Leakage Protection Without
Pollution Degree 3
Connection Pitch 25mm
Height 130mm
Width 75mm
Depth 60mm
Mechanical Durability 8,500 cycles
Electrical Durability 1,500 cycles at 415V AC
Standards IEC/EN 60947-1, IEC/EN 60947-2
Protection Degree IP20
Impact Protection IK07
Operating Temperature -25°C to +70°C
Storage Temperature -35°C to +85°C
Warranty 18 months

Key Features

  • Schneider Electric EZC100N3063 MCCB.
  • EasyPact EZC100N circuit breaker.
  • 63A rated current.
  • 3-pole 3D configuration.
  • TM-D thermal-magnetic trip unit.
  • Provides thermal overload protection.
  • Provides magnetic short-circuit protection.
  • 15kA Icu at 415V AC.
  • 18kA Icu at 380–400V AC.
  • 10kA Icu at 440V AC.
  • Up to 25kA Icu at 220–240V AC.
  • 690V AC rated insulation voltage.
  • 550V AC rated operational voltage.
  • 250V DC operational voltage.
  • 6kV impulse withstand voltage.
  • Category A MCCB.
  • Suitable for electrical isolation according to IEC 60947-2.
  • Fixed backplate mounting.
  • Front connection arrangement.
  • Toggle-operated control.
  • Positive contact-position indication.
  • Compact 75 × 130 × 60mm design.
  • 25mm connection pitch.
  • IP20 protection.
  • IK07 impact resistance.
  • Suitable for 50/60Hz AC distribution systems.

Applications

  • 63A feeder protection
  • Three-phase power distribution
  • Low-voltage electrical distribution
  • Industrial electrical panels
  • Commercial electrical panels
  • Distribution boards
  • Sub-distribution boards
  • Electrical switchboards
  • Industrial control panels
  • Building power distribution
  • Factory electrical systems
  • Overload protection
  • Short-circuit protection
  • Three-phase circuit isolation

Reviews