Schneider Electric LV516622 EasyPact CVS160B 125A 3P 3D MCCB – 25kA, TM-D Thermal-Magnetic

306.13 AED
In Stock

The Schneider Electric LV516622 EasyPact CVS160B is a 125A 3P 3D MCCB with a TM-D thermal-magnetic trip unit and 25kA breaking capacity at 380/415V AC. It provides adjustable thermal overload protection and magnetic short-circuit protection for three-phase low-voltage AC distribution systems.

In Stock
Add to wishlist2 people favorited this product
Categories: ,
Brand:

Description

The Schneider Electric LV516622 EasyPact CVS160B is a 125A 3-pole molded case circuit breaker (MCCB) designed for reliable protection and isolation in low-voltage AC electrical distribution systems. It features a 3P 3D configuration and a TM-D thermal-magnetic trip unit, making it suitable for protecting feeders, distribution circuits and electrical equipment against overload and short-circuit conditions. Schneider Electric identifies LV516622 as an EasyPact CVS160B 25kA, 380/415V AC circuit breaker.

The EasyPact CVS160B 125A MCCB is designed for 50/60Hz AC networks and provides a rated current of 125A at 50°C. Its TM-D trip unit combines thermal overload protection with magnetic short-circuit protection, providing a practical protection solution for small- and medium-sized electrical distribution systems.

The LV516622 125A MCCB has a 25kA breaking capacity at 380/415V AC, while its maximum specified Icu reaches 40kA at 220/240V AC. The breaker is therefore suitable for distribution systems where a defined short-circuit interruption capability is required at the installation’s operating voltage.

The TM-D thermal-magnetic trip unit provides an adjustable long-time pickup range of 0.7 to 1 × In, allowing the thermal overload protection to be configured according to the requirements of the protected circuit. Magnetic short-circuit protection is fixed for this configuration, providing instantaneous fault protection without requiring an electronic trip unit.

The 3P 3D configuration provides protection on all three poles and is intended for three-phase AC distribution. The breaker uses a fixed mounting arrangement, backplate mounting and front connections, making it suitable for electrical panels, switchboards and distribution boards. Its compact CVS160 frame has a width of approximately 105mm.

Schneider Electric’s EasyPact CVS range is designed with features including a double-break mechanism, standardized accessories and suitability for isolation according to IEC 60947-2. The Class II front-face insulation characteristic also supports installation in suitable Class II switchboards without insulation downgrade.

For electrical distribution applications requiring a 125A 3P MCCB, the Schneider Electric LV516622 EasyPact CVS160B offers a combination of adjustable thermal protection, magnetic short-circuit protection and 25kA breaking capacity at 415V AC, making it a suitable choice for a wide range of commercial and industrial low-voltage installations.

Specification Details
Manufacturer Schneider Electric
Product Range EasyPact CVS
Product Family EasyPact CVS100...250
Product Type Molded Case Circuit Breaker (MCCB)
Device Short Name CVS160B
Reference LV516622
Device Application Distribution
Number of Poles 3P
Protected Poles 3D
Rated Current (In) 125A at 50°C
Trip Unit TM-D
Trip Unit Technology Thermal-Magnetic
Trip Unit Rating 125A at 40°C
Protection Thermal overload + magnetic short-circuit
Network Type AC
Network Frequency 50/60Hz
Utilisation Category Category A
Breaking Capacity Code B
Icu at 220/240V AC 40kA
Icu at 380/415V AC 25kA
Ics at 220/240V AC 40kA
Ics at 380/415V AC 25kA
Ics at 440V AC 15kA
Rated Impulse Withstand Voltage (Uimp) 8kV
Long-Time Pickup Adjustment 0.7–1 × In
Long-Time Delay Fixed
Short-Time Delay Fixed
Instantaneous Pickup Fixed
Earth-Leakage Protection Without Vigi add-on
Control Type Toggle
Contact Position Indicator Yes
Mounting Fixed
Mounting Support Backplate
Connections Front
Connection Pitch 35mm
Width 105mm
Depth 86mm
Height 161mm
Mechanical Durability 25,000 cycles
Electrical Durability 12,000 cycles at 415V, In
Standards IEC/EN 60947-2
Operating Temperature According to EasyPact CVS installation requirements
Front-Face Insulation Class II
Accessory Compatibility EasyPact CVS accessory system

Key Features

  • 125A rated current for three-phase electrical distribution.
  • 3-pole, 3D MCCB configuration.
  • Schneider Electric EasyPact CVS160B frame.
  • TM-D thermal-magnetic trip unit.
  • Adjustable long-time thermal protection from 0.7–1 × In.
  • Fixed magnetic protection for short-circuit faults.
  • 25kA breaking capacity at 380/415V AC.
  • 40kA breaking capacity at 220/240V AC.
  • 15kA service breaking capacity at 440V AC.
  • Designed for 50/60Hz AC networks.
  • 8kV rated impulse withstand voltage.
  • Category A utilisation according to IEC 60947-2.
  • Suitable for electrical isolation according to IEC 60947-2.
  • Fixed backplate mounting.
  • Front connection arrangement.
  • Toggle-operated manual control.
  • Contact-position indication.
  • 25,000-cycle mechanical durability.
  • 12,000-cycle electrical durability at 415V and In.
  • Class II front-face insulation characteristic.
  • Compatible with the EasyPact CVS accessory platform.

Applications

  • Three-phase AC power distribution
  • Industrial electrical distribution
  • Commercial building distribution
  • Main distribution boards
  • Sub-distribution panels
  • Low-voltage switchboards
  • Industrial control panels
  • Feeder circuit protection
  • Machinery power distribution
  • Factory electrical systems
  • Commercial electrical panels
  • Overload protection
  • Short-circuit protection
  • Three-phase circuit isolation

Reviews

There are no reviews yet.