Schneider Electric Acti9 C60H-DC A9N61509 13A 1-Pole C-Curve DC MCB – 6kA, 250V DC

150.00 AED
In Stock

The Schneider Electric Acti9 C60H-DC A9N61509 is a 13A 1P C-curve DC MCB with 6kA breaking capacity and a 250V DC rating per pole. It provides thermal-magnetic protection against overload and short-circuit currents in DC electrical circuits and complies with IEC/EN 60947-2.

In Stock
Add to wishlist1 person favorited this product
Categories: ,
Brand:

Description

The Schneider Electric Acti9 C60H-DC A9N61509 is a 13A 1-pole DC miniature circuit breaker (MCB) designed for overcurrent and short-circuit protection in direct-current electrical circuits. It features a C-curve tripping characteristic, 6kA breaking capacity, and is rated for 250V DC per pole. Schneider Electric identifies the device as part of the Acti9 C60H-DC range and specifies compliance with IEC/EN 60947-2.

The A9N61509 DC MCB combines protection, control and isolation functions for DC circuits. Its thermal-magnetic protection helps protect electrical circuits against overload and short-circuit currents, while the compact modular construction makes it suitable for DIN-rail-mounted distribution equipment.

The C60H-DC 1P 13A configuration is rated at 250V DC and provides a 6kA Icu at this voltage. The C60H-DC family is available in 1P and 2P configurations, with the 2P versions using poles in series for higher DC voltage ratings.

The breaker is suitable for DC distribution, control circuits, battery systems and other appropriately rated DC applications where a compact miniature circuit breaker with C-curve protection is required. For photovoltaic installations, the complete system design must verify that the breaker is appropriate for the specific PV application, voltage, polarity and applicable installation standard.

Specification Details
Manufacturer Schneider Electric
Product Range Acti9 C60H-DC
Model / Reference A9N61509
Product Type DC Miniature Circuit Breaker (MCB)
Rated Current (In) 13A
Number of Poles 1P
Tripping Curve C Curve
Rated Operational Voltage 250V DC
Breaking Capacity (Icu) 6kA at 250V DC
Rated Service Breaking Capacity (Ics) 75% of Icu
Protection Technology Thermal-magnetic
Network Type DC
Standard IEC/EN 60947-2
Functions Circuit protection, control and isolation
Mounting 35mm DIN rail
Polarity Polarised; supply must follow the specified polarity
Product Width 2 modules / 18mm
Auxiliary Compatibility Auxiliary and remote-control accessories available for the C60H-DC range
Operating Temperature Refer to Schneider installation documentation for application-specific limits
Environmental Compliance RoHS compliant

Key Features

  • 13A rated current for DC circuit protection.
  • 1-pole configuration for appropriately designed DC circuits.
  • C-curve tripping characteristic.
  • 6kA DC breaking capacity at 250V DC.
  • 250V DC rated voltage per pole.
  • Thermal-magnetic protection against overload and short-circuit currents.
  • Provides protection, control and isolation functions.
  • Compact Acti9 modular design.
  • Suitable for DIN-rail installation.
  • Designed according to IEC/EN 60947-2.
  • Part of the Schneider Electric Acti9 C60H-DC family.
  • Accessories are available for remote signalling and tripping within the C60H-DC range.

Applications

The Schneider Electric Acti9 C60H-DC A9N61509 can be used for appropriately rated:

  • DC distribution circuits
  • DC control circuits
  • Battery-powered systems
  • DC auxiliary circuits
  • Industrial DC systems
  • Electrical control panels
  • DC power distribution
  • Battery energy storage applications
  • DC equipment protection
  • Solar and renewable-energy DC circuits, where the complete system design and applicable standards permit its use

Reviews