Schneider Electric MasterPact NW40H1 4000A 4-Pole Fixed ACB – 65kA, Without Trip Unit
The Schneider Electric MasterPact NW40H1 48097 is a 4000A, 4-pole fixed air circuit breaker (ACB) frame designed for high-capacity low-voltage power distribution. It features an H1 performance level with 65kA Icu at 440V AC, 690V AC rated operational voltage, and is supplied without a control/trip unit.
Description
The Schneider Electric MasterPact NW40H1 48097 is a high-current air circuit breaker frame from the MasterPact NW range, designed for demanding LV electrical distribution systems. With a 4000A rated current, 4-pole configuration and fixed mounting, it is suitable for high-capacity main incomers, bus couplers and heavy sub-distribution applications.
The MasterPact NW40H1 provides 65kA ultimate short-circuit breaking capacity (Icu) at 440V AC. Its service breaking capacity (Ics) is also 65kA, while its short-time withstand current (Icw) is rated at 65kA for 1 second and 3 seconds. The breaker is Category B and suitable for isolation according to IEC 60947-2.
The breaker has a 690V AC rated operational voltage, 1000V insulation voltage and 12kV impulse withstand voltage. The fixed construction is intended for permanent installation in a switchboard, while the supplied bare frame does not include a MicroLogic control/trip unit.
For protection and metering, the appropriate Schneider Electric MicroLogic control unit must be selected separately. For a 4-pole configuration, the final protection arrangement and required accessories should be selected according to the electrical system and single-line diagram.
| Specification | Details |
|---|---|
| Manufacturer | Schneider Electric |
| Product Range | MasterPact NW |
| Circuit Breaker Name | MasterPact NW40H1 |
| Reference / Catalogue Number | 48097 |
| Product Type | Air Circuit Breaker / Basic Frame |
| Application | Power Distribution Protection |
| Rated Current (In) | 4000A at 40°C |
| Number of Poles | 4P / 4 Pole |
| Neutral Position | Left |
| Mounting Mode | Fixed |
| Control Unit | Without Control Unit / Trip Unit |
| Performance Type | H1 – 65kA at 440V AC |
| Rated Operational Voltage (Ue) | 690V AC, 50/60Hz |
| Rated Insulation Voltage (Ui) | 1000V AC, 50/60Hz |
| Rated Impulse Withstand Voltage (Uimp) | 12kV |
| Rated Ultimate Breaking Capacity (Icu) | 65kA at 220/415V, 440V, 525V and 690V AC |
| Rated Service Breaking Capacity (Ics) | 65kA at 220/415V, 440V, 525V and 690V AC |
| Short-Time Withstand Current (Icw) | 65kA for 1s / 65kA for 3s |
| Short-Circuit Making Capacity (Icm) | 143kA at 220/415V, 440V, 525V and 690V AC |
| Selectivity Category | Category B |
| Suitability for Isolation | Yes, conforming to IEC 60947-2 |
| Network Type | AC |
| Rated Frequency | 50/60Hz |
| Control Type | Push-button |
| Sensor Rating | 2000A / 4000A |
| Circuit Breaker CT Rating | 4000A |
| Power Dissipation | 650W |
| Maximum Breaking Time | 25ms |
| Maximum Closing Response Time | <70ms |
| Mounting Support | Backplate / rails |
| Connection | Rear connection |
| Connection Pitch | 150mm |
| Mechanical Durability | 10,000 cycles without maintenance / 20,000 cycles with maintenance |
| Electrical Durability | Up to 5,000 cycles at 440V AC and 2,500 cycles at 690V AC without maintenance |
| Dimensions – Height | 352mm |
| Dimensions – Width | 537mm |
| Dimensions – Depth | 297mm |
| Approx. Net Weight | 65kg |
| Ambient Operating Temperature | -25°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Operating Altitude | 0–2,000m without derating; 2,000–5,000m with derating |
| Protection Rating | IP30 |
| Pollution Degree | 4 |
| Standard | EN/IEC 60947-1, EN/IEC 60947-2 |
| Certification | CE, CCC, EAC, ASTA |
| Mercury Free | Yes |
| Warranty | 18 months |
Key Features
- 4000A rated current
- 4-pole / 4P configuration
- MasterPact NW40H1 air circuit breaker
- Fixed-mount construction
- 65kA H1 breaking capacity at 440V AC
- 65kA Icu and Ics
- 65kA short-time withstand current
- 143kA short-circuit making capacity
- 690V AC rated operational voltage
- 1000V insulation voltage
- 12kV impulse withstand voltage
- Category B selectivity
- Suitable for isolation according to IEC 60947-2
- 2000A / 4000A sensor rating
- Rear connection
- Without MicroLogic trip/control unit
- Suitable for high-current LV power distribution
- Designed for main incomer, bus-tie and heavy feeder applications
Applications
The Schneider Electric MasterPact NW40H1 4000A ACB is suitable for:
- Main LV incomer protection
- Bus coupler / bus-tie applications
- High-capacity LV switchboards
- Industrial power distribution
- Commercial building power systems
- Data-centre electrical distribution
- Infrastructure switchboards
- Heavy industrial facilities
- Generator distribution systems
- High-current feeder protection
- Electrical distribution panels
- Retrofit and expansion of existing MasterPact NW installations
For applications where the prospective fault current exceeds 65kA, Schneider’s MasterPact NW40H2 is the higher-breaking-capacity version of the 4000A frame.
Only logged in customers who have purchased this product may leave a review.

Reviews
There are no reviews yet.