Schneider Electric MasterPact NW25H1 2500A 4-Pole Drawout Air Circuit Breaker – 65kA, Without Trip Unit

19.000.22 AED
In Stock

The Schneider Electric MasterPact NW25H1, reference 48306, is a 2500A, 4-pole drawout air circuit breaker (ACB) designed for low-voltage power distribution protection. It has an H1 performance level with 65kA breaking capacity at 440V AC and is supplied without a control/trip unit.

In Stock
Add to wishlist1 person favorited this product

Description

The Schneider Electric MasterPact NW25H1 48306 is a high-capacity 2500A air circuit breaker frame intended for demanding low-voltage electrical distribution systems. Its 4-pole configuration provides switching and protection for three-phase systems with neutral, while the drawout mounting arrangement allows the breaker to be withdrawn from its chassis for maintenance and servicing.

The MasterPact NW25H1 provides an H1 65kA short-circuit breaking capacity at 440V AC and maintains 65kA Icu/Ics ratings across the specified 220/415V, 440V, 525V and 690V AC levels. The breaker has a 690V AC rated operational voltage, 1000V insulation voltage and 12kV impulse withstand voltage.

Reference 48306 is supplied without a Micrologic control/trip unit. A suitable Micrologic control unit, matching drawout chassis and rear connections must be selected separately according to the required protection functions and switchboard configuration.

The MasterPact NW25H1 2500A ACB is suitable for applications such as main incomers, bus couplers, sub-main feeders and large LV switchboards in industrial, commercial and infrastructure installations.

Specification Details
Manufacturer Schneider Electric
Product Range MasterPact NW
Circuit Breaker Name MasterPact NW25H1
Reference / Catalogue Number 48306
Product Type Air Circuit Breaker (ACB)
Application Power Distribution Protection
Rated Current (In) 2500A at 40°C
Number of Poles 4P / 4 Pole
Mounting Mode Drawout
Control Unit Without control unit / trip unit
Performance Level H1
Rated Operational Voltage (Ue) 690V AC, 50/60Hz
Rated Insulation Voltage (Ui) 1000V AC, 50/60Hz
Rated Impulse Withstand Voltage (Uimp) 12kV
Rated Ultimate Breaking Capacity (Icu) 65kA at 220/415V, 440V, 525V and 690V AC
Rated Service Breaking Capacity (Ics) 65kA at 220/415V, 440V, 525V and 690V AC
Short-Time Withstand Current (Icw) 65kA for 1s / 65kA for 3s
Rated Short-Circuit Making Capacity (Icm) 143kA at 220/415V, 440V, 525V and 690V AC
Selectivity Category Category B
Suitability for Isolation Yes, conforming to EN/IEC 60947-2
Control Type Push-button / manually operated
Sensor Rating 1250A / 2500A
Maximum Breaking Time 25ms
Maximum Closing Response Time 70ms
Power Dissipation 600W
Connection Pitch 115mm
Mounting Support Backplate / rails
Electrical Connection Front or rear connection
Mechanical Durability 10,000 cycles without maintenance / 20,000 cycles with maintenance
Electrical Durability 5,000 cycles at 440V AC; 2,500 cycles at 690V AC
Rated Frequency 50/60Hz
Network Type AC
Ambient Operating Temperature -25 to +70°C
Neutral Position Left
Circuit Breaker Technology Air Circuit Breaker
Mercury Free Yes
Certification ASTA
Standard IEC 60947-2
Approx. Weight 49.5kg

Key Features

  • 2500A rated current
  • 4-pole / 4P configuration
  • MasterPact NW25H1 air circuit breaker
  • Drawout/withdrawable design
  • 65kA H1 breaking capacity
  • 690V AC rated operational voltage
  • 65kA short-time withstand current
  • 143kA short-circuit making capacity
  • 12kV impulse withstand voltage
  • 1000V rated insulation voltage
  • Category B selectivity
  • Suitable for isolation according to IEC 60947-2
  • Supplied without Micrologic trip/control unit
  • Suitable for large LV power distribution systems
  • Front or rear connection options
  • Designed for maintenance-friendly drawout switchgear applications

Applications

The Schneider MasterPact NW25H1 2500A ACB is suitable for:

  • Main incomer protection
  • Bus coupler / bus-tie applications
  • Large LV switchboards
  • Industrial power distribution
  • Commercial electrical distribution
  • Infrastructure power systems
  • Generator distribution systems
  • Large sub-main feeders
  • Electrical distribution panels
  • High-current low-voltage protection
  • Existing MasterPact NW switchboard extensions and maintenance

For drawout installations, the breaker must be matched with the appropriate NW chassis/cradle, Micrologic control unit and rear connection accessories.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.